The Premier Stim Plus TENS/EMS is a fully digital battery operated pulse generator that sends electrical impulses to the nerves and underlying muscle groups. This unit is a combination stimulator of TENS and EMS which can be used for pain relief and muscle stimulation. The device is provided with two controllable output channels, each independent of the other. A pair of electrodes can be connected to each output channel. The intensity level and settings are controlled by press buttons.
MECHANISM
TECHICAL DESCRIPTION
01
Channel
Dual, isolated between channels
02
Pulse AmplitudeAdjustable, 0-110 mA peak into 500 ohm load each channel. 03
Wave FormAsymmetrical Bi-Phasic Square Pulse 04
Voltage0 to 55V (Load: 500 ohm) 05
Power sourceOne 9 Volt Battery. 06
Size11.8cm(L) x 6 cm(W) x 3.1cm(H) 07
Weight157 grams with battery. 08
Pulse RateAdjustable, from 2 to 150 Hz, 1 Hz/step 09
Pulse WidthAdjustable, from 50 to 300 microseconds, 10 µs/step 10
On TimeAdjustable, 2~90 seconds , 1 Sec./ step 11
Off TimeAdjustable, 2~90 seconds , 1 Sec./ step 12
Ramp TimeAdjustable, 1~8 seconds, 1 Sec./ step, The "On"time will increase and decrease in the setting value. 13
ModeSix TENS Modes: B(Burst), N(Normal),M (Modulation Rate & Width),S1( Modulation Width), S2 (Modulation Width) and P Three EMS Modes:C(Constant), S (Synchronous), A(Alternate) 14
Burst ModeBurst rate: Adjustable, 0.5 ~ 5Hz
Pulse width adjustable, 50~300 µs
Frequency fixed = 100 Hz15
Normal ModeThe pulse rate and pulse width are adjustable. It generates continuous stimulation based on the setting value. 16
Modulation ModeModulation mode is a combination of pulse rate and pulse width modulation. The pulse rate and width are automatically varied in a cycle pattern. The pulse width is decreased by 50% from its original setting in 0.5 second, then the pulse rate is decreased by 50% from its original setting in 0.5 second. Total cycle time is 1 second. In this mode, pulse rate(2-150Hz) and pulse width(50-300µs) are fully adjustable. 17
S1 ModePulse width is automatically varied in a cyclic pattern over a nominal 10 second period. Pulse width decreases over a period of 4 seconds from the initial setting to a value 40% less.
The narrower pulse width continues for 1 second. It then increases over a period of 4 seconds to its initial setting. The cycle is then repeated. Pulse rate and pulse width are fully adjustable.18S2 ModePulse width is automatically varied in a cyclic pattern over a nominal 10 second period. Pulse width decreases over a period of 4 seconds from the initial setting to a value 70% less.
The narrower pulse width continues for 1 second. It then increases over a period of 4 seconds to its initial setting. The cycle is then repeated. Pulse rate and pulse width are fully adjustable.19Constant Mode(C)The pulse rate and pulse width are adjustable. It generates continuous stimulation is delivered . 20Synchronous Mode(S)Output from both channels occurs synchronously. The "ON" time includes "Ramp Up" and "Ramp Down" time. Therefore, the setting of ON Time should be no less than two times of the "Ramp" time in this mode. 21Alternate Mode(A)The stimulation of the CH2 will occur after Mode(A) the 1st contraction of CH1 is completed. In this mode, the setting of ON Time should be no less than two times of the "Ramp" time. The OFF Time should be equal to or greater than the ON Time.
ON TIME ≥Ramp up + Ramp down
OFF TIME ≥IN TIME22Mode PThe pre-set parameters of the 9 programs are as given below:
ProgramModePulse RatePulse WidthTimerP1Constant80Hz180µsContinueP2Burst100Hz
(Burst Rate:2Hz)180µsContinueP3-70% P.W.Modulation80Hz50µs-180µsContinueP4Mixed Frequency15Hz in 3 Sec
/2Hz in 3 Sec180µsContinueP5Mixed Frequency80Hz in 3 Sec /
2Hz in 3 Sec180µsContinueP6Constant10Hz180µsContinueP7Constant80Hz60µsContinueP8Constant80Hz180µs30 MinutesP9Burst100Hz(Burst Rate:2Hz)180µs30 Minutes23TimerAdjustable, from 5 to 60 minutes minutes and continue(C), 5 minutes each step. 24Patient
Compliance MeterThis unit can store 60 sets of operation records. Total recorded time is 999 hours. 25Low Battery IndicatorA low battery indicator will show up when the battery is low. 26Operating ConditionTemperature:0°-40°C
Relative Humidity: 30%~75%
Atmosphere Pressure : 700Hpa~1060Hpa27RemarkThere may be up to a +/-10% tolerance of all parameters and +/-20% tolerance of output amplitude & voltage. You are looking now latest Premier 6300 Stim Plus Digital Tens Machine price in pakistan market 2015 including in all major cities of Pakistan,Premier 6300 Stim Plus Digital Tens Machine Price in Karachi, Premier 6300 Stim Plus Digital Tens Machine price in Lahore ,Premier 6300 Stim Plus Digital Tens Machine in Islamabad, Sialkot, Faisalabad, Peshawar, Quetta, Multan, Rawalpindi and many more cities.
Sapiente rerum magni voluptates accusantium sequi molestias deleniti aliquid facilis commodi aut. Ea ab facere voluptatem cum beatae vero dolorem doloribus itaque culpa. Molestiae, optio, libero inventore ducimus natus incidunt qui dolor adipisci tempore tempora quo minima distinctio eligendi laborum ex quaerat eos! Unde suscipit porro est amet quis nostrum enim. Asperiores, ad, hic, culpa, rerum delectus similique minus facilis reprehenderit quisquam debitis dolores suscipit!